Upvc Window Hinges Replacement
Do your windows become difficult to open and close, or do you notice a gap in the corner? This could be due to faulty window hinges and needs to be addressed.
Standard window friction hinges, also known as 'friction stays' can be purchased from most double glazing manufacturers. To ensure that door hinge repair are functional, they must be fitted with the proper dimensions.
Track Width
Window hardware in a variety of lengths. You can measure the width of the hinge at the point that it joins to the frame to ensure you have the right size hinges. (See A measurement left, click to expand). You can also open your window and take measurements from the bottom arm to the top arm of the hinge. This is called the height of the stack. You can then compare this with the standard sizes of hinges that are available.
The most common cause of a faulty window hinge made of upvc is that the wrong size has been installed. This can be caused by fitting the wrong type of hinge or not providing enough space for the cockspur sit back into the frame. Other causes can be that the hinges aren't well-lubricated or that the window has been flung open and closed many times.
It is relatively simple to replace a pair of upvc window hinges, but it requires careful planning. The most important part of the job is ensuring you have two people who are capable of supporting the weight of the window whilst the hinges are attached to the frame. This is especially important if you are replacing hinges on a tall glazing door or window.
There are a variety of other aspects that have to be taken into consideration when ordering and fitting Upvc window hinges. You will have to consider the orientation of the window, the kind of hinge (or the way it is handled in the event of restrictor hinges), as well as the height of the stack and track width. The step-by-step directions and prompts on each page of upvc hinges make it easy to determine the specifications.
Contact us If you have any queries about the various kinds of hinges for windows or how to replace a window hinge made of upvc. We are always happy and willing to assist.
Hinge Thickness
Window hinges are a crucial part of any uPVC window. They are designed to provide the smoothest operation and durability, and are often adjustable to fine tune the window's position. These seemingly simple mechanisms are in fact complicated and intricate. They require precise engineering to work properly.
When installing hinges or replacing the ones you have installed, it is crucial to ensure that they're of the right size and type for your uPVC frame. This will prevent them from being too loose or tight and causing your window to shake and not open or close properly.
You'll require a screwdriver for removing the existing hinges and tape measure, pens or markers, calipers, and paper to take measurements. These tools will allow you to complete the task quickly and precisely.
If you're uPVC window hinges are causing gaps in the corners of your frame it's likely that they were opened incorrectly which causes them to be too low in the frame's corner. To prevent this from happening you must open the hinges in the opposite direction to the arrow and ensure that the end of each hinge is placed in the corner of your cap.
The kind of hinge you choose to use will also impact the opening of your window for example, a hinge that is side-hung will only open on the left and right sides, whereas a top hung hinge will open both the top and bottom. Some hinges also limit the amount of opening the window, which is beneficial to ensure safety in homes with small children.
Similar to the track width, it's important to keep in mind that there are numerous types of uPVC hinges available to fit your uPVC windows. These hinges include regular window hinges, restrictor hinges, and egress hinges, all of that are specifically designed for applications. It is essential to select the proper hinges for uPVC Windows.
Hinge Length
The window hinges are very simple, but they can become damaged or worn out over time. Replacing them is a simple process and can be accomplished in ten minutes or less with the right tools and preparation. If you follow the prompts on the web page and have all the necessary information available (including the correct size of the hinge for upvc) then the entire process can be completed easily. Make sure you have a second person available to support the window.
If the window won't shut or open properly, this is usually caused by the hinges being fitted incorrectly. The hinges have to be opened up correctly and positioned to the right side of the window (depending on the type - check the guide for more details). Hinges are simple to install, but it's important to read the guidelines before beginning, and also confirming with Technical Support prior to placing an order to ensure that the hinges you purchase are the right ones.
There are three kinds of upvc hinges that are available: standard hinges, restrictor hinges and fire escape hinges. The main difference between them is that fire escape hinges are designed to permit a full 90 degree opening and are compliant with Approved Document B of UK Building Regulations. Restrictor hinges have the ability to open more tightly, but are still sufficient for ventilation and can be used with top and side-hung windows.
The main factors to consider when determining the correct hinge size for your upvc window are the track outer width (18mm for H01) as well as the thickness of the hinge (13mm or 17mm) and the length of the arm (flat is 13mm while Kinked is 17mm). Choose the first hole on the track or the arm as it will be closest to the original. If the holes do not align or are not aligned, you can use the screw repair kit (available on our website) to fill in the holes originally. This will ensure a proper fit.
The window's weight should be checked once the new hinges have been put in place and the casement has been shut. This can be done by dropping the window opening onto a set of bathroom scales. If the weight is more than what is specified, reinforcement may be needed.

Friction Stay Track Length
There are many different types of friction stay hinges available for windows made of Upvc. These include standard window hinges that are restrictor hinges as well as easy clean hinges. These hinges provide a wide range of benefits to the user. They offer security, safety and long-lasting, as well being easy to install. These hinges are perfect for double-glazed or aluminum windows. They are available in a range of sizes, stack heights, and track widths that can be used with various windows.
Start by taking the distance between the bottom arm and the top arm of the hinge. It is important to measure the height of the stack. The stack height of the window hinge needs to be approximately equal to the width of the track. Then, select an option with a track of the same width as the track originally.
In addition to the standard window hinges, there are restricted and fire escape friction stays that are suitable for aluminium and upvc windows. These hinges feature an element that restricts the opening of the window. This is useful to improve child safety at home. They are also suitable for windows that are fire escapes or located in high-rise buildings.
Apart from providing security and safety These kinds of window hinges are designed to ensure an easy operation. These hinges are made of strong materials that can withstand weight of the window and its movement. They also feature a sleek design that is simple to install and doesn't require specialized tools.
Replacing a pair of upvc window hinges is an easy process, but it's crucial to determine the type you require prior to beginning. Our technical team is able to assist you if you're not sure about the kind you require. They can advise you on what is needed for your particular windows. They will be able to answer any questions and assist you in choosing the best hinges for your home. They can also send you a photo of your existing hinges so you can identify the type of hinges you require.